Litiasis doble vesical como consecuencia de dispositivo intrauterino (DIU). Reporte de un caso
ARMANDO ITURRALDE CODINA, FERNANDO GOZÁ LEÓN, WALFRIDO BEYRÍES TAMAYO, YINET ITURRALDE MUÑOZ, MARÍA ELENA RODRÍGUEZ HIDALGO
Litiasis doble vesical como consecuencia de dispositivo intrauterino (DIU). Reporte de un caso
OBJECTIVES: To report a new case of an intrauterine device causing bladder lithiasis, because of its rarity as a complication of the intrauterine device contraceptive method.METHODS/RESULTS: 27-year-old female patient admitted in the urology department of the “Hospital Medico-quirurgico 10 de Octubre” who having an intrauterine device was pregnant, underwent a caesarean section, and a new intrauterine device implant, and a few months later presented with lower urinary tract infectious syndrome, being diagnosed of double bladder lithiasis secondary to intrauterine device migration, for which cystolithotomy was performed.CONCLUSIONS: We performed a short review of the bladder foreign bodies reported in the literature, and present this case which is very unfrequent because of the finding of 2 stones in the bladder and an intrauterine device inside one of them. The intrauterine device was detected after crushing one of the calculi, 2 cm in size. It seems that first intrauterine device had migrated through the uterine wall into the bladder, creating a calcareous concretion around.
Bladder foreign bodies / Intrauterine device inside a urinary stone {{custom_keyword}} /
/
〈 |
|
〉 |